Tempest EngineeringLow temperature chillers and TCUs · Cleveland, OH Sales engineering(216) 883-6500

Hot water temperature control units to 300°F

Steam or electric heat, direct injection, shell and tube or plate and frame exchangers, in single or multiple zones, portable or stationary.

Tempest 5-zone hot water TCU with control enclosure

Vertical stacked TCUs

Multiple zones on the same application with minimal floor space. 6 kW to 18 kW heating, 10 to 50 GPM, closed loop cooling through shell and tube or brazed plate, or open loop direct injection. Good for small and medium extrusion and mixing.

Multi-zone mixer TCUs

Separate zone controls for mixer rotors, close or long coupled pumps, electric immersion heating with on/off or modulating control, and ASME code stamped exchangers.

Medium-to-high flow TCUs

Single or multi-zone skids with zones placed horizontally for easy access to pumps and control valves. Made for mill and calender work, with solid state or SCR heater controls.

Hot water TCU builds

  • 5-zone, 9 kW hot water TCU for industrial rubber tubes

    250°F design · 5 zones

    5-zone, 9 kW hot water TCU for industrial rubber tubes

    Heating
    9 kW
    Fluid
    Water
    Operating
    50°F to 250°F
    Electrical
    NEMA 12
    Controls
    Watlow EZ Zone
  • 2-zone steam heated TCU for tire manufacturing

    210°F design · 2 zones

    2-zone steam heated TCU for tire manufacturing

    Heating
    Steam
    Fluid
    Water
    Design pressure
    100 PSIG
    Operating
    50°F to 250°F
    Electrical
    NEMA 12 indoor duty
  • 1-zone, 24 kW TCU for rubber shoe sole manufacturing

    250°F design · 1 zone

    1-zone, 24 kW TCU for rubber shoe sole manufacturing

    Heating
    24 kW
    Fluid
    Water
    Design pressure
    150 PSIG
    Pump
    Close coupled centrifugal
    Cooling
    Shell and tube

Chiller down? 24/7/365 emergency service for industrial refrigeration, including ammonia and cascade systems, on Tempest and other makes.

Call (216) 883-6622

Common questions

How hot do hot water units run?

Up to 300°F.

Steam or electric?

Either. Steam heated exchangers are ASME code stamped; electric uses immersion heaters with on/off or modulating control.

Get a quote: Hot water units (300°F)

Prefer to talk? Sales (216) 883-6500. Chiller down? (216) 883-6622, 24/7.

  1. Load: max and min cooling or heating load (tons, kW or BTUH).
  2. Fluid: type, flow rate (GPM), supply and return temperatures.
  3. Area classification: non-hazardous, or Class 1 Div 2 Group B, or C and D.

Call salesGet a quote