Ice rink chillers: ammonia or HFC, one sheet or several

We have engineered, built and serviced ice plant chillers for over 35 years, for seasonal rinks and year-round arenas.

Tempest chiller skid with compressor and control panel

Ammonia ice rink chillers

15-20% more efficient than HFC systems, a refrigerant 60% less expensive than R-507, and a natural refrigerant with no delisting issues.

HFC ice rink chillers

Lower initial investment, lower lifecycle maintenance costs and simpler safety requirements.

Options

Water, air or evaporative cooled condensers. Open drive reciprocating, screw or semi-hermetic compressors. 24/7 remote monitoring and troubleshooting.

Ice rink chiller projects

  • 15°F SST · 100 tons

    100-ton air-cooled HFC ice rink chiller, one NHL sheet

    Refrigerant
    R-507
    Fluid
    50% ethylene glycol
    Compressors
    (2) semi-hermetic twin screw
    Evaporator
    DX exchanger
    Controls
    Allen Bradley CompactLogix PLC
  • 15°F SST · 142 tons

    142-ton air-cooled ammonia ice rink chiller, one sheet

    Refrigerant
    R-717
    Fluid
    40% ethylene glycol
    Compressors
    Open drive 6 and 8 cylinder
    Dispersion tanks
    (2) 1,800 gallon stainless
    Evaporator
    Flooded shell and tube with surge drum
    Included
    Tempest installation and cold glycol system
  • 15°F SST · 205 tons

    205-ton ammonia ice rink chiller, two sheets (one Olympic, one NHL)

    Condensing
    Evaporative-cooled
    Refrigerant
    R-717
    Fluid
    40% ethylene glycol
    Compressors
    (3) open drive 6-cylinder recip
    Dispersion tank
    3,600 gallon stainless
    Controls
    Allen Bradley CompactLogix PLC

What a Tempest system aims for

  • Up to 50% less energy
  • Up to 100% waste heat recovery
  • Up to 50% water recovery
  • 30+ year life expectancy
  • Zero ozone depletion refrigerants

Chiller down? 24/7/365 emergency service for industrial refrigeration, including ammonia and cascade systems, on Tempest and other makes.

Call (216) 883-6622

Common questions

Ammonia or HFC for a rink?

Ammonia runs 15-20% more efficient and has no delisting concerns; HFC costs less up front and has simpler safety requirements. We build both.

Do you install the system?

Yes. Our 142-ton ammonia rink chiller included Tempest installation and the cold glycol system.

Get a quote: Ice rink chillers

Prefer to talk? Sales (216) 883-6500. Chiller down? (216) 883-6622, 24/7.

  1. Load: max and min cooling or heating load (tons, kW or BTUH).
  2. Fluid: type, flow rate (GPM), supply and return temperatures.
  3. Area classification: non-hazardous, or Class 1 Div 2 Group B, or C and D.

Call salesGet a quote