Low and ultra-low temperature industrial chillers
Most Tempest projects fall between 20°F and -60°F. Below -60°F we build cascade chillers with separate high side and low side refrigerant circuits.

Designed in-house, built in Cleveland
Our in-house engineering department designs, engineers and manufactures each system, so you get a chiller built for your application, on a skid from our 70,000 sq ft plant.
How cold, and how
Single stage mechanical refrigeration to -40°F, two stage to -60°F, cascade systems to -80°F and liquid nitrogen systems down to -160°F. Typical ultra-low cascade chillers run 10 to 25 tons.
Refrigerants and layouts
Natural refrigerants (ammonia, propane, CO2) or HFCs (R-134A, R-507, R-1234ZE, R-1234YF). Air, water or evaporative cooled; direct expansion or flooded.
- Low temperature
- +20°F to -59°F
- Ultra-low
- -60°F to -112°F
- Tonnage
- 5 to 800 tons
- Area rating
- Class 1, Div 2
Low temperature chiller projects
Applications
- Ice rink chillers
- CBD oil extraction
- Test chamber chillers (R&D)
- Explosion proof, Class 1 Div 2
- Process fluid pumping systems
- Containerized chiller systems
Chiller down? 24/7/365 emergency service for industrial refrigeration, including ammonia and cascade systems, on Tempest and other makes.
Call (216) 883-6622Common questions
How cold can a Tempest chiller go?
Cascade systems reach -80°F, ultra-low projects on our site run to -105°F and -112°F, and liquid nitrogen exchange systems go down to -160°F.
Can you build to our existing specification?
Yes. We can design to an existing specification package, or work with you to define the process specifications first.
What tonnage do you build on one skid?
Low temperature chillers are skid-designed, typically 10 to 300 tons on a single skid.
More Tempest equipment
- Explosion proof chillers
- CBD extraction chillers
- Ice rink chillers
- Ammonia chillers
- Containerized chillers
- Air cooled chillers
- Water cooled chillers
- Hot water units (300°F)
- Hot oil units (700°F)
- Portable mini-TCUs
- Chiller and TCU combo systems
- Chiller pumping systems
- Cooling tower pumping systems
- Deionized water systems
- Allen Bradley PLC controls
- Service and parts
- Preventative maintenance
Get a quote: Low temperature chillers
Prefer to talk? Sales (216) 883-6500. Chiller down? (216) 883-6622, 24/7.
- Load: max and min cooling or heating load (tons, kW or BTUH).
- Fluid: type, flow rate (GPM), supply and return temperatures.
- Area classification: non-hazardous, or Class 1 Div 2 Group B, or C and D.